Concrete Frame Shear Wall Strengthening

concrete frame shear wall strengthening - carbon fiber and steel plate

A hotel has an 18-story frame shear wall structure with a construction area of approximately 23,508 m2. The 1st to 3rd floors are the lobby, catering, fitness and entertainment, and conference service spaces. The 4th ~ 6th floors are the hotel's internal staff offices, catering and changing rooms. The 7th to 9th floors are apartment-style office floors. The 10th to 18th floors are standard rooms and superior business rooms. The hotel officially started the construction of the pile foundation in December 2004. Later, due to funding problems of the construction party, the construction of the hotel was suspended in 2008. When the construction was suspended, the main structure was capped. The project was idle for 8 years. At the beginning of 2016, the owner changed its use function to a four-star hotel and resumed construction. In order to meet the use function of the main structure, the main structure is tested, and the structure that does not meet the requirements needs to be reinforced.


The existing problems of the main structural concrete members: some concrete members have low concrete strength and fail to meet the design strength requirements. Some concrete components have excessive carbonation depth, exposed tendons, cracks, and corrosion of steel bars.


On the basis of rechecking the bearing capacity of the main structure of the hotel, the analysis concluded that: due to the low concrete level of some components, the bearing capacity of some components cannot meet the requirements of the design specifications, and corresponding reinforcement should be carried out. Excessive carbonation depth, cracks, steel corrosion, etc. of some concrete components will affect the normal use performance and durability of the building and must be treated.



Structural reinforcement treatment plan


Frame column: The concrete column whose concrete strength is low and cannot meet the requirements of bearing capacity shall be reinforced with externally bonded steel.


steel jacketing of concrete column          steel jacketing of concrete column


Frame beams: The concrete beams with low concrete strength that cannot meet the bearing capacity requirements are reinforced by sticking steel plates.

beam strengthening with steel plate


Cast-in-place slab: For concrete slabs whose concrete strength is low and cannot meet the requirements of bearing capacity, the method of sticking carbon fiber fabric on the bottom of the slab is used for reinforcement.

carbon fiber strengthening slab



After the project is reinforced according to the above-mentioned reinforcement plan, after inspection and acceptance, all indicators can meet the design requirements, the reinforcement effect is good, and the cost is low. It has been in use for two years and has a good structure, which meets the requirements for use after functional changes, and achieves the effects of safety, reliability, economic feasibility and convenient construction.

ผลิตภัณฑ์ที่แนะนำโดย Horse Construction

คุณสามารถหาได้ทุกสิ่งที่คุณต้องการที่นี่ ไว้วางใจและลองใช้ผลิตภัณฑ์เหล่านี้ คุณจะพบความแตกต่างอย่างมากหลังจากนั้น

แผ่นเหล็กยึดติดอีพ็อกซี HM-120

กาวยึดติดแผ่นเหล็กโครงสร้าง HM-120 เป็นผลิตภัณฑ์อีพ็อกซีสองส่วนที่มีการยึดเกาะที่แข็งแรง บ่มที่อุณหภูมิห้อง มีคุณสมบัติป้องกันการเสื่อมสภาพ ทนต่อแรงกระแทกได้ดีเยี่ยม ทั้งการยึดติดด้วยตนเองและการยึดติดร่วมกันของเหล็กและคอนกรีต โดยมีอัตราการเฉือนสูง ใช้สำหรั

เพิ่มเติม >

HM-120M กาวอีพ็อกซี่สำหรับการเคลือบแผ่นเหล็ก

HM-120M กาวเคลือบแผ่นเหล็กเป็นกาวอีพ็อกซี่ชนิดใหม่ที่ดัดแปลงมาเพื่อใช้เคลือบโครงสร้างอาคารโดยเฉพาะ เพื่อใช้เสริมแท่งเหล็กที่ยึดด้วยกาว สามารถยึดติดกับพื้นผิวและโลหะต่างๆ ได้ โดยมีข้อดี เช่น ความแข็งแรงในการยึดติดสูง ความเหนียวและความแข็งแรงในการเฉือนที่ยอด

เพิ่มเติม >

HM-30 พอลิเมอร์เสริมคาร์บอนไฟเบอร์ (CFRP)

ผ้าคาร์บอนไฟเบอร์ที่มีความแข็งแรงสูงทิศทางเดียวที่ผ่านการทำให้อิ่มตัวล่วงหน้าเพื่อสร้างผ้าโพลีเมอร์เสริมคาร์บอนไฟเบอร์ (CFRP) ซึ่งใช้สำหรับเสริมความแข็งแรงให้กับองค์ประกอบคอนกรีตโครงสร้าง

เพิ่มเติม >

Back
Top
Close